Serial In / Out<br />
Provided for daisy-chained communications from the <strong>Genesys</strong> computer<br />
and through all the Master (and Monitor) cards.<br />
2 x FireWire<br />
Two FireWire ports, labelled A and B, are provided for daisy-chaining the<br />
FireWire.<br />
Wordclock In<br />
A BNC connector is provided for receiving Wordclock sync if this card is<br />
selected to act as the Master sync input for the entire AD/DA system.<br />
Only one instance of the sync source has to be provided to the console,<br />
and the FireWire software window specifies where the sync needs to be<br />
connected to.<br />
Wordclock Out<br />
If Wordclock has been selected as the sync source then this sync signal<br />
will also be output on the Wordclock Out BNC.<br />
It is useful for when the console is running as the sync master (set to<br />
work with Internal sync) and other pieces of equipment need to sync to<br />
the console.<br />
Switchblock 1<br />
Board States<br />
Contains 3 switches and should be set as shown left:<br />
Debug: For <strong>AMS</strong> <strong>Neve</strong> use only.<br />
In normal operation, this switch should be in the down position.<br />
Serial: Enables the communications to be daisy-chained, and must be set<br />
to the up position.<br />
Reset: For <strong>AMS</strong> <strong>Neve</strong> use only.<br />
In normal operation, this switch should be in the down position.<br />
Switchblock 2<br />
Board ID<br />
These 2 switches should only be set once the card has been installed in<br />
the console:<br />
• 0 = switch in the Up position<br />
• 1 = switch in the Down position<br />
The first & second switches set the card's ID and tells the card where in<br />
the system it is.<br />