Meterbridge<br />

CHANNEL Meters<br />

Each fader strip meter has 2 scales:<br />

• VU scale, displayed to the left<br />

• dBu scale, displayed to the right<br />

Beneath this, a bank of 15 leds displays the following information:<br />

MIX<br />

Indicates whether the Monitor path or Channel path is contributing to the<br />

L and R of the Main Mix.<br />

MTR<br />

The MTR led indicates whether the meter is sourced from the CH I/P,<br />

DAW Send or DAW Return.<br />

8T 1 to 8T 8 leds<br />

For LCR channel strips<br />

In it's default state, these leds indicate which of the 8T busses the<br />

Channel Input is routed to.<br />

▶ When the routing is interrogated (by pressing the >8T button at the<br />

bottom of the channel strip), these leds will indicate which of the 8T<br />

busses the Monitor Input is routed to for the length of time the button is<br />

pressed.<br />

For Stereo channel strips<br />

Indicates whether the Channel or Monitor path is being sent to each of the<br />

8T busses.<br />

SIG<br />

The SIG (Signal Presence) led lights depending on the threshold of the<br />

SIG PRES rotary control on the Master Select panel.<br />

GR<br />

The GR (Gain Reduction) led lights to show any compression that may be<br />

applied to the path.<br />

It is a tri-state led and will light either:<br />

• Green (light compression)<br />

• Orange (medium), or<br />

• Red (heavy)<br />