30.11.2014 Views

Genesys User Manual - AMS Neve

Genesys User Manual - AMS Neve

Genesys User Manual - AMS Neve

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SYSTEM<br />

The list of Panels on the left side of the screen shows not only which<br />

panels have been detected (as indicated by a 'Y' being shown against it),<br />

but also which internal communications link each panel is communicating<br />

on.<br />

If there are two stars against any panel, this shows that there is a<br />

difference between which panels have been detected on this boot cycle, as<br />

opposed to the last time the console was booted.<br />

The screen also shows which panels have been detected on boot-up, in<br />

other words, how many Reverb modules, how many monitor boards etc,<br />

plus which channel-strips have been detected in each 8-fader section.<br />

This screen therefore informs you know which panels have established<br />

valid communications with the computer.<br />

Any panel that is shown with a '^' symbol next to it indicates that it is in<br />

programming/boot mode, if this is the case then the panel requires a<br />

firmware update, please follow the section below Update Firmware to do<br />

this.<br />

Always quote the<br />

software Version &<br />

Build numbers when<br />

communicating with <strong>AMS</strong><br />

<strong>Neve</strong> Technical Services<br />

about any software<br />

issues.<br />

NB:<br />

A panel that has no communications with the PC may still pass audio, but<br />

other functions like changing the order of processing or changing the<br />

audio routing may not be available.<br />

If there has been a change in the number of panels detected when the<br />

console and the computer first boots up from power-up, a screen will warn<br />

you that the configuration of the console has changed.<br />

The right side of the screen shows you:<br />

• the Software Version number<br />

• the Software Build number<br />

Update Firmware<br />

Opens the Update Firmware screen, that allows all of the panels in the<br />

console to have their firmware updated.<br />

This is necessary when updating console software or going between<br />

different versions of console software, which also require supporting<br />

firmware on the modules in the console.<br />

This function allows you to update all of the firmware on the individual<br />

panels on the console.<br />

As new features are introduced or methods of operation change you will<br />

have up-to-date panel firmware.<br />

The <strong>Genesys</strong> console software contains all of the files needed for updating<br />

each of these panels (as long as the <strong>Genesys</strong> Applications Hex Files option<br />

was ticked during the console software installation i.e. the default<br />

installer options/settings were NOT changed during software<br />

installation).<br />

On a 16 fader console, it will take about an hour to update all of the<br />

panels.<br />

▶ To begin the firmware update from the <strong>Genesys</strong> main screen Click<br />

System / Update Firmware, and the Update Firmware screen will open.<br />

- 118 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!