SYSTEM<br />
The list of Panels on the left side of the screen shows not only which<br />
panels have been detected (as indicated by a 'Y' being shown against it),<br />
but also which internal communications link each panel is communicating<br />
on.<br />
If there are two stars against any panel, this shows that there is a<br />
difference between which panels have been detected on this boot cycle, as<br />
opposed to the last time the console was booted.<br />
The screen also shows which panels have been detected on boot-up, in<br />
other words, how many Reverb modules, how many monitor boards etc,<br />
plus which channel-strips have been detected in each 8-fader section.<br />
This screen therefore informs you know which panels have established<br />
valid communications with the computer.<br />
Any panel that is shown with a '^' symbol next to it indicates that it is in<br />
programming/boot mode, if this is the case then the panel requires a<br />
firmware update, please follow the section below Update Firmware to do<br />
this.<br />
Always quote the<br />
software Version &<br />
Build numbers when<br />
communicating with <strong>AMS</strong><br />
<strong>Neve</strong> Technical Services<br />
about any software<br />
issues.<br />
NB:<br />
A panel that has no communications with the PC may still pass audio, but<br />
other functions like changing the order of processing or changing the<br />
audio routing may not be available.<br />
If there has been a change in the number of panels detected when the<br />
console and the computer first boots up from power-up, a screen will warn<br />
you that the configuration of the console has changed.<br />
The right side of the screen shows you:<br />
• the Software Version number<br />
• the Software Build number<br />
Update Firmware<br />
Opens the Update Firmware screen, that allows all of the panels in the<br />
console to have their firmware updated.<br />
This is necessary when updating console software or going between<br />
different versions of console software, which also require supporting<br />
firmware on the modules in the console.<br />
This function allows you to update all of the firmware on the individual<br />
panels on the console.<br />
As new features are introduced or methods of operation change you will<br />
have up-to-date panel firmware.<br />
The <strong>Genesys</strong> console software contains all of the files needed for updating<br />
each of these panels (as long as the <strong>Genesys</strong> Applications Hex Files option<br />
was ticked during the console software installation i.e. the default<br />
installer options/settings were NOT changed during software<br />
installation).<br />
On a 16 fader console, it will take about an hour to update all of the<br />
panels.<br />
▶ To begin the firmware update from the <strong>Genesys</strong> main screen Click<br />
System / Update Firmware, and the Update Firmware screen will open.<br />