Master Card ID 1 switch ID 0 switch<br />

1 0 0<br />

2 0 1<br />

3 1 0<br />

4 1 1<br />

These IDs are used by the Board Mapping software window to determine<br />

which physical positions the Master cards occupy.<br />

1-8 9-16 17-24 25-32 Monitor 33-40 41-48 49-56 57-64<br />

section<br />

Master 1 Slave Master 2 Slave Master 3 Slave Master 4 Slave<br />

ID: 0 0 0 1 1 0 1 1<br />

It is only the Master card that needs to have its position within the console<br />

set.<br />

In the diagram above, each numbered Master card is shown with its Slave<br />

in position on a 64-fader console, along with the ID switch settings for<br />

each Master card.<br />

Please note, this is a typical configuration and customers may decide to<br />

put Master cards in different positions.<br />

The Monitor Section card does not require ID switches to be set.<br />

Once you have set these ID switches, please see the section on Board<br />

Mapping on page 147.<br />

WCLCK 75Ω Termination<br />

Set this switch to the up position if you have Wordclock sync coming into<br />

this card.<br />

This will terminate the Wordclock input signal.<br />