CAT 5 connections on systems without AD/DA Monitor card<br />

Channel Slave Audio Link Channel Slave Audio Link Channel Slave Audio Link Channel Slave Audio Link<br />

1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3<br />

1 - 8 9 – 16 17 – 24 25 – 32 33 – 40 41 – 48 49 – 56 57 - 64<br />

Master Slave Master Slave Master Slave Master Slave<br />

In Out In Out In Out In<br />

<strong>Genesys</strong><br />

computer<br />

USB to CAT5 converter cable – into the first Serial In on 17-24 Master<br />

card, then out of Serial Out, into Serial In on 1-8, out of Serial Out, to Serial In on<br />

33-40 and so on.<br />

On a system without a Monitor card, the comms goes from the <strong>Genesys</strong><br />

computers into the 17-24 Master card, then this signal goes to 1-8, 33-40<br />

and finally 49-56.<br />

Wordclock Sync<br />

In Out*<br />

1 - 8 9 – 16 17 – 24 25 – 32 Monitoring 33 – 40 41 – 48 49 – 56 57 - 64<br />

Master Slave Master Slave Master Slave Master Slave<br />

The Wordclock Sync can only be accepted by the left-hand most Master<br />

card (or the Monitor card if this is left-most) using the WCLK IN BNC<br />

connector.<br />

This Wordclock sync is then internally distributed from this single point to<br />

all the other cards in the system.<br />

The Wordclock sync is also output (on the adjacent WCLK OUT BNC<br />

connector) should it be needed to feed other pieces of equipment.<br />

* If the WCLK OUT connector is used, it should be terminated by setting<br />

the 75Ω switch as shown on page 127.<br />