TB Trim<br />
Whenever a Talkback is activated anywhere on console, this trim pot sets<br />
the amount by which the monitoring will dim.<br />
This is a global setting that applies the same dim value when any of the<br />
Talkback to CUE1, CUE2, TB, SLATE or TB ALL buttons are pressed.<br />
It has a range of 0dB to -40dB.<br />
▶ To set this value, press and hold down any of the CUE1, CUE2, TB or<br />
SLATE buttons on the Talkback panel. The value of the TB Trim will be<br />
displayed relative to the Monitor Level or Master Dim level on the Monitor<br />
Knob alpha display.<br />
▶ While holding the above button down, turn the trimpot above the<br />
Master Dim button until the desired value is reached.<br />
NB:<br />
Factory set to -20dB<br />
The Main Mix fader level forms<br />
part of the console snapshot, so<br />
this level will always be<br />
reinstated on boot-up<br />
However, to prevent a loud<br />
burst of audio through the<br />
monitoring, the monitoring level<br />
control will always come back as<br />
if turned fully down to CUT.<br />
Main Monitor Pot<br />
In it's default state, this controls the monitoring level to the speakers, the<br />
level being displayed underneath in the alpha display window.<br />
The control ranges from OFF, through -56dB to 0dB.<br />
However, between -14db and -18dB, the display of -15* refers to a fixed<br />
operating level of 85dB.<br />
It is at this level that the control should be set when calibrating external<br />
speakers and amplifiers.<br />
By pressing the knob, it is possible to set up the DIM, AFL, PFL and SIF<br />
levels.<br />
▶ Press the knob to set the DIM level (the DIM led will light).<br />
The dim level will be shown on the alpha display and has a range of 0dB<br />
to -36dB.<br />
▶ Rotate the knob to set the value.<br />
Whenever DIM is pressed on the Control Room Monitor panel, it will dim<br />
by this amount, relative to the LS Monitor level.<br />
▶ Press the knob again to set the AFL level (the AFL led will light).<br />
The AFL level will be shown on the alpha display and has a range of 0dB<br />
to -36dB.<br />
▶ Rotate the knob to set the value.<br />
In Safe mode, whenever an AFL is pressed anywhere on the console, the<br />
AFL signal will be at this amount, relative to the LS Monitor Level.<br />
▶ Press the knob again to set the PFL level (the PFL led will light).<br />
The PFL level will be shown on the alpha display and has a range of 0dB<br />
to -36dB.<br />
It will not be possible to<br />
change any of these settings<br />
if the Lock Monitor Level<br />
pref is ticked in Settings.<br />
In Safe mode, whenever a PFL is pressed anywhere on the console, the<br />
PFL signal will be at this amount relative to the LS Monitor Level.<br />
▶ Rotate the knob to set the value.<br />
▶ Press the knob again to set the SIF (Solo In Front) level (the SIF led<br />
will light).<br />
The SIF percentage will be shown on the alpha display, and ranges from<br />
30% to 100%<br />
• 100% indicates you are listening to 100% of the AFL signal and<br />
nothing else.<br />
- 78 -