TERM<br />

Control mode<br />

CPAP<br />

CPAP mode<br />

Display window<br />

EEPROM<br />

Event<br />

Exhaled tidal volume<br />

Expiratory hold<br />

Extended features<br />

f<br />

Flow<br />

Flow trigger<br />

f/Vt<br />

f/Vt f<br />

I:E ratio, monitored<br />

I:E ratio, calculated<br />

Inspiratory hold<br />

L<br />

Leak compensation<br />

LED<br />

lpm<br />

DEFINITION<br />

A ventilation mode where the ventilator delivers machine breaths at a<br />

set rate. In Control Mode, patient triggers are not allowed.<br />

Continuous Positive Airway Pressure. The ventilator continuously<br />

maintains Positive gas pressure through the patient circuit during the<br />

entire breath cycle.<br />

A ventilation mode where the patient triggers all breaths. Available<br />

breath types are Pressure Support and Spontaneous.<br />

A set of 12 dot-matrix displays used to show monitored data, alarm<br />

messages and Extended Feature menu items.<br />

Electrically Erasable Programmable Read Only Memory. Nonvolatile<br />

electronic memory that is used by the ventilator to maintain calibration<br />

data, control setting and other data when power is not applied to the<br />

ventilator.<br />

Any condition noted in the ventilator’s event trace. This may include<br />

both error conditions and normal operational events.<br />

See Tidal Volume.<br />

A maneuver which holds the expiratory phase of a delivered breath for<br />

a duration sufficient to determine the AutoPEEP of a patient.<br />

A set of ventilator controls and options that are not associated with<br />

front panel controls. Extended Features are accessed through a menu<br />

shown in the display window.<br />

See Total Breath Rate, monitored.<br />

The velocity of gas delivery to the patient, quantified in lpm.<br />

A patient effort in which the amount of bias flow routed into the<br />

patient’s lungs exceeds the Sensitivity setting. A flow trigger will result<br />

in delivery of an Assist or Patient breath, according to the ventilation<br />

mode.<br />

Total Breath Rate divided by the average Exhaled Tidal Volume.<br />

Total Breath Rate divided by the average Exhaled Tidal Volume, and<br />

the Total Breath Rate.<br />

The ratio of the inspiration period to the expiration period for a breath.<br />

The lesser value is normalized to 1.<br />

Calculated Inspiratory:Expiratory ratio, based upon the Inspiratory<br />

Time setting and the Breath Rate setting<br />

A maneuver which holds the inspiratory phase of a volume delivered<br />

breath for a duration sufficient to determine ∆ Pres pressure and static<br />

lung compliance of the patient.<br />

Liters<br />

Leak Compensation improves triggering when a circuit leak is present.<br />

Light Emitting Diode. An indicator that is illuminated on the front panel.<br />

Liters Per Minute. Flow rate.<br />