TERM<br />

Pressure support breath<br />

Pressure Trigger<br />

PSIG<br />

rpm<br />

Scrolling, monitored data<br />

display<br />

SIMV<br />

SIMV mode<br />

Spontaneous breath<br />

Spontaneous Breathing<br />

Trial (SBT)<br />

Tidal volume, monitored<br />

(Vte)<br />

Total breath rate,<br />

monitored (f)<br />

Transducer<br />

Vcalc<br />

VE<br />

Volume control breath<br />

Vte<br />

DEFINITION<br />

A patient breath where the circuit pressure is raised to an operator-set<br />

pressure and maintained until flow decreases to an operator-set<br />

percentage of the peak flow achieved. Pressure Support Breaths may<br />

also be terminated by an operator-set maximum time, or by exceeding<br />

2 breath periods.<br />

A patient effort in which the pressure below PEEP is less than the<br />

Sensitivity setting. A pressure trigger will result in a delivered breath.<br />

Pounds per Square Inch Gauge. A unit for measuring pressure.<br />

Revolutions per minute. Turbine speed is measured in rpm.<br />

Displays the monitored values statically or allows for automatic<br />

scrolling. While scrolling is active, each monitored value will be<br />

displayed for 3 seconds then the next value will be automatically<br />

displayed.<br />

Synchronized Intermittent Mandatory Ventilation.<br />

A ventilation mode where a minimum number of machine or assist<br />

breaths are given, and the patient is allowed to trigger additional<br />

Patient breaths. Available breath types are volume control, pressure<br />

support, and spontaneous.<br />

A breath which the patient starts and cycles. Spontaneous breaths are<br />

cycled at 10% of peak flow, set variable time termination, or when they<br />

exceed 2 breath periods.<br />

A ventilation mode used to temporarily minimize ventilatory support<br />

and perform clinical assessments of a patient’s dependence on, or<br />

ability to be removed from positive pressure ventilation.<br />

The exhaled volume quantified at the patient wye. Exhaled volume is<br />

measured for all breath types.<br />

The quantity of breaths given per minute; includes all breath types.<br />

A measuring device. Transducers can be used to quantify flow or<br />

pressure.<br />

A monitor that displays the calculated peak flow for volume control<br />

breaths. Vcalc is calculated based on the set tidal volume and the set<br />

inspiratory time.<br />

See minute volume, monitored.<br />

A machine or assist breath where a operator-set volume is delivered<br />

over a operator-set time. Flow is delivered in a decelerating waveform<br />

where the peak and final flows are calculated so that the final flow is<br />

50% of the peak flow.<br />

See tidal volume, monitored.<br />