<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

C Bit 140<br />

C Bit 141<br />

C Bit 142<br />

C Bit 143<br />

C Bit 144<br />

C Bit 145<br />

C Bit 146<br />

C Bit 147<br />

Description:<br />

2nd +X Axis Software Limit Choice<br />

2nd -X Axis Software Limit Choice<br />

2nd +Y Axis Software Limit Choice<br />

2nd -Y Axis Software Limit Choice<br />

2nd +Z Axis Software Limit Choice<br />

2nd -Y Axis Software Limit Choice<br />

2nd +4th Axis Software Limit Choice<br />

2nd -4th Axis Software Limit Choice<br />

1 st software limit: Using parameter 1006 ~ 1013 to set the limit. After executing zero return<br />

procedure, the parameter setting value will be enabled. The booting default<br />

value of +ive direction is 99999.999mm and the booting default value of –ive<br />

direction is -99999.999mm.<br />

2 nd software limit: Using parameter 1034 ~ 1041to set the limit. After executing zero return<br />

procedure, the parameter setting value will be enabled. The booting default<br />

value of +ive direction is 99999.999mm and the booting default value of –ive<br />

direction is -99999.999mm.<br />

The corresponding C BIT of each axis can exchange any value between the 1st software limit<br />

and the 2nd software limit. This means that only one set/combination can be enabled at tone<br />

time within the limit of the 1 st software limitation and the 2 nd software limitation.<br />

Software Limit<br />

C BIT<br />

X axis +ive direction C140: When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

X axis -ive direction C141: When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

Y axis +ive direction C142: When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

Y axis -ive direction C143:When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

Z axis +ive direction C144:When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

Z axis -ive direction C145:When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

4th axis +ive direction C146:When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

4th axis -ive direction C147:When OFF, use 1 st software limit;<br />

software limit<br />

When ON, using 2 nd software limit.<br />

X axis Moving Range (C140<br />

X axis Moving Range<br />

(Para. # 0071 is 1、C129 is ON)<br />

X axis Moving Range(C140 OFF)<br />

X axis Moving Range<br />

(Para. # 0071 is 1、C129 is OFF)<br />

+X<br />

+ X axis<br />

1 st soft limit<br />

G22 travel limit: Able to designated the embedded travel checking range. For Internal and<br />

- X axis<br />

Direction G22<br />

+ X axis<br />

Direction G22<br />

<strong>LNC</strong> Technology Co., Ltd. 95