<strong>LNC</strong>-<strong>M600</strong><br />

Machine Adjustment<br />

7.2 Laser Compensation Procedure<br />

R(MAC Coord.)<br />

1<br />

-X<br />

2<br />

3<br />

4 5<br />

Total Length = ABS(Q) * K<br />

K+3<br />

Arg. U to Decide Effective or Not<br />

K+4<br />

E(Cancel Distance of Backlash)<br />

Q(Each Section Measurement)<br />

K+5<br />

2K+5<br />

K+7<br />

K+6<br />

:Repaidly Ori. G00<br />

E(Cancel Distance of Backlash)<br />

:Linear Inter G01<br />

:Pro. Pause M0<br />

:Stop G04<br />

:Pro. Finish<br />

Program Argument Description<br />

1. A:Axis direction, 1 means X axis, 2 means Y axis and 3 means Z axis.<br />

2. E:Delete backlash moving distance. If it is a positive value, at beginning of<br />

measuring, the program should move ABS(E)distance toward this axis<br />

positive direction. Then moving ABS(E)distance toward negative direction<br />

(Step 2 and Step 3 from the above Diagram). After measuring forward direction,<br />

first moving ABS(E)distance toward negative direction and then moving ABS<br />

(E)distance toward positive direction (Steps K+4 and K+5 from the above<br />

diagram). If it is a negative value, then using the opposite method. So, if this<br />

axis pitch error compensation direction is positive, then this argument must be<br />

set as negative value. If it is a negative direction compensation, then this<br />

argument must be set as positive.<br />