<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

S Bit 062<br />

Description:<br />

MPG Dry Run<br />

ON/OFF control on the communication style software Panel will communicate with LADDER<br />

through this signal. For MPG Dry Run key on the software Panel, ON/OFF control will<br />

communicate with LADDER through this signal. The timing procedure is as following:<br />

S062<br />

C020<br />

S068<br />

S Bit 063<br />

Description:<br />

Auxiliary Function Lock<br />

ON/OFF control on the communication style software Panel will communicate with LADDER<br />

through this signal. For AUXILIARY FUNCTION LOCK key on the software Panel, ON/OFF<br />

control will communicate with LADDER through this signal. The timing procedure is as<br />

following:<br />

S063<br />

C046<br />

S047<br />