<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

WARNING ID<br />

Warning Message<br />

OP 6001 X AXIS OVER MLC TRAVEL LIMIT (+)<br />

OP 6002 X AXIS OVER MLC TRAVEL LIMIT (-)<br />

OP 6003 Y AXIS OVER MLC TRAVEL LIMIT (+)<br />

OP 6004 Y AXIS OVER MLC TRAVEL LIMIT (-)<br />

OP 6005 Z AXIS OVER MLC TRAVEL LIMIT (+)<br />

OP 6006 Z AXIS OVER MLC TRAVEL LIMIT (-)<br />

OP 6007 4TH AXIS OVER MLC TRAVEL LIMIT (+)<br />

OP 6008 4TH AXIS OVER MLC TRAVEL LIMIT (-)<br />

Warning/Alarm Cancel:<br />

After the above system warning message is enabled, need to wait until the servo moves toward<br />

the opposite direction. And also, the corresponding C BIT changes from ON to OFF, the<br />

warning message will be removed automatically.<br />

In JOG/RAPID or MPG mode, if the system warning message (OP 6001 〜 OP 6008) of MLC<br />

travel limit occurs, it is okay not to remove the warning message. Just moving directly to the<br />

reverse direction away from where the warning message occurs. After getting away from the<br />

software limitation range, the warning message will be removed.<br />

Under mode of MEM, MDI or HOME, if the system warning message (OP 6001 〜 OP 6008) of<br />

MLC travel limit occurs, OP will send out the warning message. In this case, users must press<br />

“RESET” to reset the system.<br />

ALARM ID<br />

OP 1020<br />

Warning Message<br />

OVER MLC TRAVEL LIMIT<br />

C Bit 059<br />

C Bit 060<br />

C Bit 061<br />

C Bit 062<br />

Description:<br />

X Axis Interlock<br />

Y Axis Interlock<br />

Z Axis Interlock<br />

4th Axis Interlock<br />

When the corresponding axis is ON, the axis will NOT move. But, the coordinate value will be<br />

renewed.<br />

C Bit 066<br />

C Bit 067<br />

C Bit 068<br />

C Bit 069<br />

Description:<br />

X Axis: Select Axis Direction Signal of Handle INT<br />

Y Axis: Select Axis Direction Signal of Handle INT<br />

Z Axis: Select Axis Direction Signal of Handle INT<br />

4th Axis: Select Axis Direction Signal of Handle INT<br />

Assumed NC is under MEM mode. User can use <strong>Manual</strong> Handle Interrupt function to<br />