<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

52 NUMBER OF 1ST SPINDLE.2A GEAR<br />

667 NUMBER OF 2ND SPINDLE.2A GEAR<br />

675 NUMBER OF 3RD SPINDLE.2A GEAR<br />

Range: 1 ~ 32767<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 1<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

this parameter is to set the numerator of the 2 nd spindle gear ratio. When the<br />

spindle is at the 2nd gear, C BIT 097 is ON.<br />

If this ratio is greater than 1, it is a deceleration relationship between the motor<br />

and the spindle. If this ratio is smaller than 1, it is an acceleration relationship<br />

between the motor and the spindle.<br />

57 1ST SPINDLE FEEDBACK MULTIPLY<br />

890 2ND SPINDLE FEEDBACK MULTIPLY<br />

894 3RD SPINDLE FEEDBACK MULTIPLY<br />

Range: 1 ~ 4<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 1<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

this parameter is to set ENCODER feedback multiple factor of spindle, this<br />

parameter works only when the ENCODER feedback multiple factor of spindle<br />

is AB PHASE (setting value of Parameter 0195 is 0); if the ENCODER feedback<br />

multiple factor of spindle is CW/CCW or PULSE/DIRECTION (setting value of<br />

Parameter 0195 is either 1 or 2), then the feedback multiple factor of spindle is<br />

1 permanently.<br />

Assumed the spindle control method is PULSE COMMAND (under spindle<br />

orientation and rigid rapping modes), the multiple product of this parameter<br />

setting value and parameter #1116 setting value (total pulse per rotation of<br />

spindle motor ENCODER) is the PLUSE command value that is sent by NC in<br />

order to make spindle motor to rotates one time. If the spindle control method is<br />

V COMMAND, then the multiple product of this parameter setting value and the<br />

parameter 1116 setting value will only be used to calculate the actual rotational<br />

speed of spindle.<br />

889 2ND SPINDLE ENCODER PPR<br />

893 3RD SPINDLE ENCODER PPR<br />

Range: 1 ~ 32767<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 1024<br />

value:<br />

176 <strong>LNC</strong> Technology Co., Ltd.