<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1157 MAX SPEED OF 1RD SPINDLE GEAR<br />

Range: 0 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 3000<br />

value:<br />

Unit: RPM<br />

Description assumed the spindle is at the 3 rd gear, when the spindle<br />

:<br />

rotational speed (spindle S Code command * rotational speed OVERRIDE) is<br />

over this parameter setting value, the system will be restricted this parameter<br />

setting value.<br />

200 <strong>LNC</strong> Technology Co., Ltd.