<strong>LNC</strong>-<strong>M600</strong><br />

SYSTEM ALARM and WARNING<br />

INT 3172:CUT UP CHAMFER OVER RANGE<br />

INT 3201:COMP UNIT VECTOR 0<br />

(1)Compensation unit vector is 0.<br />

(2)System error, please contact supplier.<br />

(3)Press RESET to clear wrong warning message<br />

INT 3202:COMP START UP ARC<br />

(1)Compensating start-up is arch.<br />

(2)Please start compensating according to G00/G01.<br />

(3)Press RESET to clear wrong warning message.<br />

INT 3203:COMP CANCEL ARC<br />

(1)Compensating cancel is arch.<br />

(2)Please cancel compensation according to G00/G01.<br />

(3)Press RESET to clear wrong warning message.<br />

INT 3204:COMP LINE DET 0<br />

(1)DETERMINE values is 0.<br />

(2)Check part program.<br />

(3)System error, please contact supplier.<br />

INT 3205:COMP VECTOR LENGTH 0<br />

(1)DETERMINE values is 0.<br />

(2)Check part program.<br />

(3)System error, please contact supplier.<br />

INT 3206:COMP INTERFERENCE<br />

(1)Over cutting interference occurs.<br />

(2)Decrease compensation radius or modify part program pathway.<br />

(3)Press RESET to clear wrong message error.<br />

INT 3207:COMP NO INTERSECTION<br />

(1)Not able to find the intersect points while calculating compensation value.<br />

(2)Decrease compensation radius or modify part program pathway.<br />

( 3 ) Press RESET to clear wrong warning message.<br />