<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

rebooting default value 99999.999 um. If this parameter setting value is larger<br />

than parameter # 1006 (+ive X-axis<br />

software travel limit), it will enable the alarm system (MOT 4005, 1 st software<br />

traveling limit setting error). The -ive X axis 1 st and 2 nd software traveling limit is<br />

able to execute exchanging through C BIT 141. Please refer to the description<br />

of C BIT. Under the condition that the -ive X axis 1 st software traveling limit is<br />

enabled, when X axis will excess the restricted range, it will enable the alarm<br />

system (MOT 9002 X axis over the –ive software travel limit) or (MOT 4058 over<br />

the software travel limit). Please refer to the description of this warning<br />

message.<br />

1034 2ND X+ SOFT LIMIT<br />

1036 2ND Y+ SOFT LIMIT<br />

1038 2ND Z+ SOFT LIMIT<br />

1040 2ND 4+ SOFT LIMIT<br />

Range: -99999999 ~ 99999999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 99999999<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

this parameter is to set the limitation value of the +ive X axis software travel<br />

limit. It works only after X axis is completed zero return procedure, or using the<br />

rebooting default value 99999.999 um. If this parameter setting value is smaller<br />

than parameter # 1035 (-ive X axis<br />

software travel limit), it will enable the alarm system (MOT 4023, 2 nd software<br />

traveling limit setting error). The +ive X axis 1 st and 2 nd software traveling limit is<br />

able to execute exchanging through C BIT 140. Please refer to the description<br />

of C BIT. Under the condition that the +ive X axis 2 nd software traveling limit is<br />

enabled, when X axis will excess the restricted range, it will enable the alarm<br />

system (MOT 9001 X axis over the +ive software travel limit) or (MOT 4058 over<br />

the software travel limit). Please refer to the description of this warning<br />

message.<br />