<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

815 SPIKE -X CMP VALUE<br />

825 SPIKE -Y CMP VALUE<br />

831 SPIKE -Z CMP VALUE<br />

Range: 0 ~ 200<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

assumed doing the circular testing. When the spike value of -ive X axis direction<br />

is 0, this means NOT to enable the spike compensation function of -ive X-axis<br />

direction.<br />

816 SPIKE -X CMP TIME<br />

826 SPIKE -Y CMP TIME<br />

832 SPIKE -Z CMP TIME<br />

Range: 0 ~ 200<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

Please check the controller’s actual disconnecting time interval first and then set<br />

the value. Assumed doing canned cycle testing. When set the spike time<br />

interval to 0, it means NOT to enable the spike compensation function of -ive<br />

X-axis direction.<br />

210 <strong>LNC</strong> Technology Co., Ltd.