<strong>LNC</strong>-<strong>M600</strong><br />

Appendix B: Servo Connection Example<br />

B4 TOSHIBA converter<br />

Starting & AUTO – TUNING Steps:<br />

Please Follow the below Parameter Adjustment Steps after Power ON:<br />

1.Para. vL:Base frequency #1(25 ~ 400 )<br />

(Normal setting value is 60).<br />

2.Para. F306:Voltage of base frequency(output voltage adjustment)<br />

(Normal setting value is 0 ~ 600V).<br />

3.Para.F411:Nμmber of poles of motor(2、4、6、8、10、12、14、16、18)<br />

(Normal setting value is 4).<br />

4.Para.F412:Rated capacity of motor( 0.1 ~ 280kw)<br />

Setting value is according to Output ratio on motor brand.<br />

5.Para.F413:Motor type( 0 ~ 4)<br />

(Normal setting value is 4).<br />

6. Executing auto-tuning.<br />

Para.F400:To set auto-tuning selection as 2(auto-tuning enabled)<br />

7. When auto-tunning is finish, inverter will auto-save the new parameter after testing.<br />

Para.F401 ~ F410 auto-setting value.<br />

8.Finish Steps 1~7 and doing CW/CCW testing.<br />

Para.Fr(Forward/Reverse selection) 0:Forward 1:Reverse<br />

(This parameter is effective on OP operation method. )<br />

9. To set Para.cnod(operation command mode selection)to 1.<br />