<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1097 1ST SPINDLE D/A SCALE RPM/10V<br />

Range: 1 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 6000<br />

value:<br />

Unit: RPM<br />

Description<br />

:<br />

this parameter is to set the corresponding spindle rotational<br />

speed when the spindle motor input voltage is 10V.<br />

1116 1ST SPINDLE ENCODER PPR<br />

Range: 1 ~ 32767<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 1024<br />

value:<br />

Unit: pulse<br />

Description Assumed total pulse per rotation of spindle motor ENCODER is 2500, this<br />

:<br />

means this parameter is set to 2500. Please refer to parameter # 0057 for<br />

setting description.<br />

196 <strong>LNC</strong> Technology Co., Ltd.