<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

4.5 S Bits Desctiption<br />

S Bit 000<br />

Description:<br />

Cycle Start Light<br />

When the system accepts to enable “CYCLE START” key and enters into automatic executing<br />

condition, this signal is ON, which means the system is in the “Cycle Start” condition. This<br />

signal is OFF when the automatic executing completed or the system is in ”FEED HOLD”<br />

condition.<br />

S Bit 001<br />

Description:<br />

Feed Hold Light<br />

When this signal is ON, it means the system is in ”FEED HOLD” condition. So the system is in<br />

“Machine Stop” condition.<br />

S Bit 002<br />

S Bit 003<br />

S Bit 004<br />

S Bit 005<br />

S Bit 006<br />

S Bit 007<br />

S Bit 008<br />

Description:<br />

Edit Mode Light<br />

MEM Mode Light<br />

MDI Mode Light<br />

JOG Mode Light<br />

INC JOG Mode Light<br />

MPG Mode Light<br />

Home Mode Light<br />

When these signals are ON, it means the system is in the relative operation mode condition.<br />

S Bit 010<br />

Description:<br />

Preparation Completed<br />

When these signals are ON, the system is in “Preparation Complete” condition.<br />

S Bit 011<br />

Description:<br />

MDI keyboard press signal<br />

1. The signal will be sent from system when pressing the bottom on MDI.<br />

2. The signal notify MLC to turn on LCD power and recount time to turn off LCD power.<br />