14.01.2015 Views

LNC-M600 Leading Numerical Controller Maintenance Manual

LNC-M600 Leading Numerical Controller Maintenance Manual

LNC-M600 Leading Numerical Controller Maintenance Manual

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

40 MIN.F OVERRIDE VALUE FOR G00<br />

Range: 0 ~ 25<br />

Active: Active After RESET<br />

Level: User<br />

Default 10<br />

value:<br />

Unit: %<br />

Description This parameter is to set the correspondent % value of RAPID TRAVERSE when<br />

:<br />

the feedrate OVERRIDE knob is set to 0%. For example, is this parameter is set<br />

as 10, when the OVERRIDE knob is set to 0%, actually it corresponds to 10%.<br />

53 FEEDBACK MUL FACTOR.4TH<br />

54 FEEDBACK MUL FACTOR.X<br />

55 FEEDBACK MUL FACTOR.Y<br />

56 FEEDBACK MUL FACTOR.Z<br />

Range: 1 ~ 4<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 4<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

This parameter is to set the feedback multiply factor of the X-axis ENCODER<br />

and is effect only when X-axis ENCODER feedback signal is set as AB PHASE<br />

(i.e. Parameter # 0191 set as 0). If the X-axis ENCODER feedback signal is set<br />

as CW/CCW or PULSE/DIRECTION (i.e. Parameter # 0191 set as 1 or 2), the<br />

feedback multiply factor remains 1 all the time.<br />

In PULSE COMMAND mode, the value is the product of this parameter set<br />

value and the set value of Parameter #0058 (i.e. ppr) is the total pulse per<br />

rotation that NC intents to let the X-axis motor to achieve.<br />

156 <strong>LNC</strong> Technology Co., Ltd.