<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

140 DISABLE RESET COMMON VAR CLR<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

Default 1<br />

value:<br />

Unit: Nul<br />

Description there are 500 command variables and all level programs share these common<br />

:<br />

variables. The default value is VACANT for common variables @1 ~ @400<br />

when rebooting. But, whether or not clear means VACANT is decided by this<br />

parameter when press RESET. For common<br />

variables @401 ~ @500, remaining as the original value after pressing RESET<br />

key and also remaining power-discontinue memory. @0 means VACANT<br />

permanently.<br />

141 DISABLE RESET GLOBAL VAR CLR<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description there are 33 local variables and program in each level program has its own 33<br />

:<br />

local variables. Only need to end that level program to clear local variables of<br />

that level. Since pressing RESET key will return back to the main program level,<br />

the content of local variables in the main program level will use this parameter<br />

to set whether or not to clear when pressing RESET. If rebooting, local variables<br />

will be cleared no matter in which local level. #0 means VANCANT permanently.<br />

142 ABS/RLT ROTATION COMMAND<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

0:absolute value<br />

1:incremental value<br />

please refer to program manual for a full detailed description.<br />

143 CODE FOR SCALING<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

236 <strong>LNC</strong> Technology Co., Ltd.