<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

817 SPIKE -X CMP DELAY<br />

827 SPIKE -Y CMP DELAY<br />

833 SPIKE -Z CMP DELAY<br />

Range: 0 ~ 200<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

Please check the controller’s actual disconnecting time interval first and then set<br />

the value. Assumed doing canned cycle testing. Delay time interval between the<br />

spike point of X axis -ive direction and the direction changing point.<br />

1018 COMP DIST OF EACH SECTION.X<br />

1019 COMP DIST OF EACH SECTION.Y<br />

1020 COMP DIST OF EACH SECTION.Z<br />

1021 COMP DIST OF EACH SECTION.A<br />

Range: 0 ~ 99999999<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 30000<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

Assumed pitch error compensation interval is 10000μm of every X axis section,<br />

so please set this parameter to 1000.<br />

<strong>LNC</strong> Technology Co., Ltd. 211