<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

813 SPIKE +X CMP TIME<br />

819 SPIKE +Y CMP TIME<br />

829 SPIKE +Z CMP TIME<br />

Range: 0 ~ 200<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

Please check the controller’s actual disconnecting time interval first and then set<br />

the desired value. Assumed doing circular testing. When set the spike time<br />

interval to 0, it means NOT to enable the spike compensation function of +ive<br />

X-axis direction.<br />

814 SPIKE +X CMP DELAY<br />

820 SPIKE +Y CMP DELAY<br />

830 SPIKE +Z CMP DELAY<br />

Range: 0 ~ 200<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

Please check the controller’s actual disconnecting time interval first and then set<br />

the value. Assumed doing circular testing. Delay time interval between the spike<br />

point of +ive X-axis direction and the direction changing point.<br />