<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1183 OFFSET LINEAR SCALE OF X AXIS<br />

1184 OFFSET LINEAR SCALE OF Y AXIS<br />

1185 OFFSET LINEAR SCALE OF Z AXIS<br />

1186 OFFSET LINEAR SCALE OF 4TH AXIS<br />

Range: 0 ~ 99999999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

This parameter is only applicable to Heidenhain’s linear scale with multiple<br />

reference marks. To change the set value of this parameter, please press<br />

RESET first and execute zero return manually again. By measuring 2 or 3<br />

signal intervals of the linear scale, NC can detect instantly the relative position<br />

between each axis’s current position and the linear scale’s zero point. If the two<br />

positions do not match each other, the shift between them must be defined by<br />

setting this parameter.<br />