Appendix B: Servo Connection Example<br />

When torque produced in low speed range is not large enough, it can be boosted up by<br />

increasing the torque boost rate with this parameter<br />

This parameter can be used with:<br />

PE=0(V/f constant)<br />

PE=1(square reduction)<br />

PE=6(V/f 5-point setting)<br />

(Note)This value must not be too high. Everytime’s incremental can not be over2% of<br />

setting value, or over current will occur.<br />

Base-frequency F306<br />