<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

108 MORTOR GAINS.X<br />

109 MORTOR GAINS.Y<br />

110 MORTOR GAINS.Z<br />

111 MORTOR GAINS.4TH<br />

Range: 1 ~ 20000<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 200<br />

value:<br />

Unit: RPM/1V<br />

Description<br />

:<br />

using this parameter to set the corresponding rotational speed (RPM) when the<br />

X axis motor entry voltage is 1V. When the entry voltage is 10V, the X axis<br />

motor rotational speed is 2000RPM, which means the parameter setting value is<br />

200. This parameter is effective only when X axis control method is V<br />

COMMAND (Setting value of Parameter 0156 is 3).<br />