<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

S Bit 074<br />

Description:<br />

Optional Stop<br />

ON/OFF control on the communication style software Panel will communicate with LADDER<br />

through this signal. For Optional Stop key on the software Panel, ON/OFF control will<br />

communicate with LADDER through this signal. The timing procedure is as following:<br />

S074<br />

C044<br />

S044<br />

S Bit 080<br />

S Bit 081<br />

S Bit 082<br />

S Bit 083<br />

Description:<br />

M00 Read<br />

M01 Read<br />

M02 Read<br />

M30 Read<br />

M00:after interpreting as M00, this signal is ON(remain one time scanning time)<br />

M01:after interpreting as M01, this signal is ON(remain one time scanning time)<br />

M02:after interpreting as M02, this signal is ON(remain one time scanning time)<br />

M30:after interpreting as M03, this signal is ON(remain one time scanning time)<br />

S Bit 086<br />

Description:<br />

Orientation Finish<br />

When spindle orientation is completed, this signal is ON. When PLC cancels the spindle<br />

orientation command (C85), this signal will become OFF.<br />