<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1118 ENABLE INDEX PROTECTED FUNCTION<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description:When the distance between the 1 st index and limit switch is less than 1/5 or<br />

more than 4/5 revolution of the encoder, grid protection function will activate so<br />

the next index mark will be used to make the distance between the 1 st index and<br />

limit switch over 1/2 revolution of the encoder if the distance in-between is less<br />

than 1/2 revolution. This function ensures that the zero point is always the<br />

original one.<br />

1171 SPACE1 LINEAR SCALE OF X AXIS<br />

1172 SPACE2 LINEAR SCALE OF X AXIS<br />

1173 SPACE1 LINEAR SCALE OF Y AXIS<br />

1174 SPACE2 LINEAR SCALE OF Y AXIS<br />

1175 SPACE1 LINEAR SCALE OF Z AXIS<br />

1176 SPACE2 LINEAR SCALE OF Z AXIS<br />

1177 SPACE1 LINEAR SCALE OF 4TH AXIS<br />

1178 SPACE2 LINEAR SCALE OF 4TH AXIS<br />

Range: 0 ~ 99999999<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 20020<br />

value:<br />

Unit: um<br />

Description:This parameter is only applicable to Heidenhain’s linear scale with multiple<br />

reference marks. For the setting method, please go to the figure below for<br />

reference.<br />

10.02<br />

9.98<br />

10.04<br />

9.96<br />

Parameter No. 1171<br />

Parameter No. 1172<br />

Unit:mm<br />

<strong>LNC</strong> Technology Co., Ltd. 225