<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

210 HOME POINT FOR LINEAR SCALE<br />

Range: 0 ~ 63<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description:This parameter is only applicable to Heidenhain’s linear scale with multiple<br />

reference marks. Please use BIT to set the relative position of each axis’s<br />

machine zero point and the linear scale’s zero point (Only valid when the<br />

relevant BIT value to parameter No. 0209 is set to 1).<br />

0:Machine zero point is at the positive side of the linear scale’s reference mark;<br />

1:Machine zero point is at the negative side of the linear scale’s reference<br />

mark.<br />

293 ZRN BY DOG OR INDEX<br />

Range: 0 ~ 63<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description:BIT0:0 means X axis uses DOG for machine reference point reference and 1<br />

means X uses motor INDEX signal for reference.<br />

BIT1:0 means Y axis uses DOG for machine reference point reference and 1<br />

means Y uses motor INDEX signal for reference.<br />

BIT2:0 means Z axis uses DOG for machine reference point reference and 1<br />

means Z uses motor INDEX signal for reference.<br />

220 <strong>LNC</strong> Technology Co., Ltd.