<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

800 RANGE.X FOR EXACT REACH<br />

801 RANGE.Y FOR EXACT REACH<br />

802 RANGE.Z FOR EXACT REACH<br />

803 RANGE.4TH FOR EXACT REACH<br />

Range: 1 ~ 20000<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 500<br />

value:<br />

Unit: um<br />

Description This parameter is to set the bound value of in-position check window of X axis<br />

:<br />

when G00 exact stop is enabled. (Please refer to parameter # 0043). When |<br />

X-axis command position – X-axis axis actual position | ≦ parameter set value,<br />

X-axis has accomplished G00 exact stop.<br />

845 X AXIS LINEAR/ROTARY TYPE<br />

846 Y AXIS LINEAR/ROTARY TYPE<br />

847 Z AXIS LINEAR/ROTARY TYPE<br />

Range: 0 ~ 1<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description:0:Linear axis is set for X axis and ball screw pitch is set according to actual<br />

value.<br />

1:Rotary axis is set for X axis and ball screw pitch is set to 360 o .<br />