14.01.2015 Views

LNC-M600 Leading Numerical Controller Maintenance Manual

LNC-M600 Leading Numerical Controller Maintenance Manual

LNC-M600 Leading Numerical Controller Maintenance Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

5.4 Spindle Parameter<br />

16 ACC/DEC TIME OF 1ST SPINDLE<br />

885 ACC/DEC TIME OF 2ND SPINDLE<br />

888 ACC/DEC TIME OF 3RD SPINDLE<br />

Range: 0 ~ 32767<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 1000<br />

value:<br />

Unit: MS/KRPM<br />

Description<br />

:<br />

This parameter sets the corresponding output voltage of Spindle rotation and<br />

acc/deceleration speed of Pulse command. When Spindle rotational signal uses<br />

voltage output, user must sets OFFSET of voltage output signal and the<br />

corresponding RPM of 10 V.<br />

21 1ST SPD ORIENTATION RPM<br />

Range: 1 ~ 20000<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 100<br />

value:<br />

Unit: RPM<br />

Description this parameter is used to set rotational speed of spindle orientation . When the<br />

:<br />

spindle orientation is doing machine adjustment, the spindle rotational speed is<br />

decided by this parameter. In order to prevent any error by different rotational<br />

speed, please do NOT modify this parameter setting value after machine<br />

adjustment of spindle orientation is completed.<br />

<strong>LNC</strong> Technology Co., Ltd. 173

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!