<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1065 1ST SPD RIGTAP ACCELERATED COMP<br />

Range: 0 ~ 100000<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description after rigid tapping is completed, please set the commanding<br />

:<br />

compensation value as the display value of data system #022 at<br />

(Diagnostic) DGNOS page.<br />

1066 1ST SPD RIGTAP VELOCITY FILTER<br />

Range: 0 ~ 20<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description the bigger the value, the less vibration will occur. , but the<br />

:<br />

bigger the rigid tapping following error will be. When enter 0, this means<br />

there is no filting effect. When enter the maximum value (i.e., 20), this<br />

means there is a completely filting effect, which means the signal is filited<br />

completely. Please adjust this parameter setting value during the rigid<br />

tapping machine adjustment.<br />

<strong>LNC</strong> Technology Co., Ltd. 193