MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

4.7 MLC Window Function<br />

After Ladder key-in the desired item codes in R60 〜 R62, setting C640 (0: read, 1 write).<br />

When completed, using C65 to inform NC. NC will enter the desired item into the<br />

corresponding R register (C64 is 0) according to the setting of R60 〜 R62 and C64. Or<br />

read the setting value (C64 is 1) from the corresponding R register. When completed the<br />

task, using S79 to inform Ladder. This function is enabled (raising edge trigger) when C65<br />

becomes 1 from 0; S79 will become OFF after C65 has become OFF.<br />

R register definition:<br />

R Register Definition Remarks<br />

60<br />

61<br />

62<br />

63<br />

64<br />

Item Code<br />

1:read absolute coordinate value;<br />

2:read machine coordinate value;<br />

3:read & write macro global variables;<br />

4:read parameter value;<br />

1:read only;<br />

2:read only;<br />

3:read & write。<br />

4:read only;<br />

Sub-Item Code 1 (different depends on R60)<br />

R60:3, means the starting numbers of macro global<br />

variables(1 ~ 500) that are read and wrote<br />

R60:4, the starting parameter #s that are read<br />

Sub-Item Code 2 (different depends on R60 and<br />

R61)<br />

Use R61 and R62 to order<br />

R60:3,means the desired read/write macro global read and write multiple<br />

variables’ numbers (starting from the number that is macro global variables<br />

designated by R61),maximum 8.<br />

continuously (max 8<br />

R60:4,means the desired read/write parameter variables),or the designated<br />

variables’ numbers(starting from the number that is parameter continuously<br />

designated by R61) ,maximum 8.<br />

Read/Write Value (different depends on R60~R62)<br />

R60:1,means X axis absolute coordinate mm part;<br />

R60:2,means X axis machine coordinate mm part;<br />

R60:3,means the present value of the1 st macro Please refer to Attention.<br />

global variable that is designated by R61 and R62.<br />

R60:4,means the value of 1 st parameter that is<br />

designated by R61 and R62.<br />

Read/Write Value (different depends on R60~R62)<br />

R60:1,means X axis absolute coordinate um part;<br />

R60:2,means X axis machine coordinate um part;<br />

R60:3,means the present value of the1 st macro Please refer to Attention.<br />

global variable that is designated by R61 and R62.<br />

R60:4,means the value of 1 st parameter that is<br />

designated by R61 and R62.<br />