MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

C Bit 201<br />

C Bit 202<br />

C Bit 203<br />

C Bit 204<br />

Description:<br />

Absolute encoder Reset Ready Signal:X Axis<br />

Absolute encoder Reset Ready Signal:Y Axis<br />

Absolute encoder Reset Ready Signal:Z Axis<br />

Absolute encoder Reset Ready Signal:4th Axis<br />

When LADDER finishes absolute encoder zero return, this signal needs to be sent out to notify<br />

NC that.<br />

C Bit 207<br />

C Bit 208<br />

C Bit 209<br />

C Bit 210<br />

Description:<br />

Absolute Encoder Data Ready Signal:X Axis<br />

Absolute Encoder Data Ready Signal:Y Axis<br />

Absolute Encoder Data Ready Signal:Z Axis<br />

Absolute Encoder Data Ready Signal:4th Axis<br />

LADDER will notify NC when driver enters into ABS transmitting mode and driver data are<br />

ready.<br />

C Bit 213<br />

C Bit 214<br />

C Bit 215<br />

C Bit 216<br />

Description:<br />

Absolute Encoder Data Bit 0Transmitting Signal : X Axis<br />

Absolute Encoder Data Bit 0Transmitting Signal : Y Axis<br />

Absolute Encoder Data Bit 0Transmitting Signal : Z Axis<br />

Absolute Encoder Data Bit 0Transmitting Signal : 4th Axis<br />

Assumed absolute encoder data reading is sent by serial transmitting. Also, assumed 2 bits of<br />

Encoder will be transmitted every time. So, when this bit is ON, it indicates that the signal of<br />

transmitting 2 bits data from driver to NC is 1.<br />