<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1072 WIDTH OF PULSE RISING<br />

Range: 1 ~ 50<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 20<br />

value:<br />

Unit: us<br />

Description In PULSE COMMAND type, this parameter is to set the pulse wid, as shown in<br />

:<br />

the below figure. The pulse cycle can be expressed in the below formula. (linear<br />

axis)<br />

Pulse Upper<br />

Period: T<br />

1 feedrate<br />

= × GR × Pulse/rev<br />

T pitch<br />

×<br />

1<br />

60000<br />

, unit:ms<br />

Example: X-axis pitch = 10mm, gear ratio is 2(deceleratin ratio, motor rotates<br />

2 times and ball screw rotates one time). In the condition when it takes 10000<br />

Pulses for the motor to complete a rotation, if the feedrate is set as<br />

2000mm/min, then the pulse amount per 1ms should be:<br />

Pulses =<br />

2000<br />

10<br />

× 2 × 10000 ×<br />

Commanding Pulse Rush Period is:<br />

T<br />

=<br />

1000<br />

67<br />

1<br />

60000<br />

≈ 15us<br />

≈ 67pulses/ms<br />

Under this condition and the condition of maintaining pulse rush is 50% of<br />

DURATION (High/Low Standard Position Time), the raising width shoue be set<br />

as 7us.<br />

If the setting value of this parameter is too big, it is possible to cause the raising<br />

width of the pulse rush over the period in high speed motion. This will further<br />

cause the commanding pulse rush to double with each other. At this time, motor<br />

DRIVER will not able to do the determination correctly, which will make the<br />

servo motor not able to rotate normally.<br />

But, if the setting value is too small, the motor DRIVER still not able to do the<br />

determination. So, the maximum setting value of this parameter should be<br />

under the max motion speed (G00). Also the upper limit is the width of the<br />

non-double commanding pulse rush rows. The smallest value should be the<br />

smallest width value that the motor DRIVER is able to determine.<br />