<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1076 JOG SPEED OF 2ND SPINDLE<br />

1077 JOG SPEED OF 3RD SPINDLE<br />

1121 JOG SPEED OF 1ST SPINDLE<br />

Range: 0 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 200<br />

value:<br />

Unit: RPM<br />

Description<br />

:<br />

When C BIT 072 is ON, spindle will rotate in this parameter’s setting rotational<br />

speed.<br />

1150 SPEED OF 1ST SPINDLE GEAR<br />

Range: 0 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: RPM<br />

Description this parameter is to determine whether or not to do gear<br />

:<br />

shifting motion according to the spindle S code command.<br />

1. when the spindle is at 1 st gear and assuming that the user command of the<br />

spindle S code command is larger than (not including equal to) this<br />

parameter setting value, the system will inform PLC to do the gear shifting<br />

motion (shifting to which gear depends on the spindle commanding<br />

rotational speed);<br />

2. when the spindle is NOT at 1 st gear and assuming that the user command<br />

of the spindle S code command is smaller than (including equal to ) this<br />

parameter setting value, the system will inform PLC to shift the spindle to<br />

the 1 st gear;<br />

3. if no spindle gear shifting need, recommend to use the 4 th gear (C BIT<br />

097 – 099 are OFF) and set this parameter to 0.<br />

Need to pay attention to the following: NC only follow S code command from the<br />

user command of to determine the desired gear and then to inform PCL to<br />

execute gear shifting motion. If due to the spindle rotational speed OVERRIDE,<br />

which cause the actual rotational speed is over that gear range, then NC will<br />

NOT execute the above motion.<br />

1151 SPEED OF 2ND SPINDLE GEAR<br />

Range: 0 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: RPM<br />

Description this parameter is to determine whether or not to execute the<br />

:<br />

gear shifting motion according to the spindle S code command.<br />

1. when the spindle is at 2 nd gear and assuming that the spindle S code<br />

<strong>LNC</strong> Technology Co., Ltd. 197