<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

method is force setting.<br />

64 HOME DOG 0)NC 1)NO<br />

Range: 0 ~ 1<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description:this parameter works only when the home DOG sensor signal<br />

is connected to LOCAL INPUTS (Transit Board HS1 〜 HS4 connect<br />

points). (Parameter 0175 setting value is 0). If the home dog sensor signal<br />

is connected REMOTE INPUTS, then PLC ladder diagram program needs<br />

to change each axis home DOG signal state to C BIT 0031 〜 0035 in<br />

order to inform NC.<br />

76 ENABLE ABS SET AFTER HOMING<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 1<br />

value:<br />

Unit: Nul<br />

Description:please refer to 1014 ~ 1017 for absolute coordinate setting<br />

value. After each servo axis returns home, display value of absolute<br />

coordinate is determined by following three points:<br />

a. setting value of parameters 1014 ~ 1017;<br />

b. 00 coordinated system, setting value of G54 ~ G59 coordinate system;<br />

c. setting value in G52 area coordinate system.<br />

⎛00<br />

coordinate value<br />

⎞<br />

⎜<br />

⎟<br />

Para#1014 ~ 1017 value − ⎜+<br />

G54 ~ G59 coordinate value ⎟<br />

⎜<br />

⎟<br />

⎝+<br />

G52 regional coordinate value ⎠<br />

In addition,<br />

a. setting value of parameters 1014 ~ 1017: use this parameter to decide<br />

whether or not they are effective;<br />

b. 00 coordinate system, G54 ~ G59 coordinate system setting values:<br />

effective permanently;<br />

c. setting value in G52 area coordinate system: use parameter 0133 to decide<br />

whether or not it is effective.<br />