<strong>LNC</strong>-<strong>M600</strong><br />

MLC <strong>Maintenance</strong> -- C,S Bits and Register<br />

C Bit 036<br />

Description:<br />

Emergency Stop<br />

When this signal is ON, the system is in RESET condition and all motions stop, which means<br />

the system condition is NOT READY.<br />

C Bit 037<br />

Description:<br />

External Reset<br />

System outer RESET signal which is the same function as pressing RESET bottom.<br />

C Bit 038<br />

Description:<br />

M, S, T Finish<br />

Assumed NC is in the MEM or MDI mode. When the program executes M code interpretation,<br />

the content of M Code will be sent by REG 1. At the same time, it will send out M Code Read<br />

(MF)signal.<br />

When LADDER finishes executing the related M Code and replies it back to M,S,T Finish<br />

(FIN)signal, the signal will inform the system that the executing of M code is completed.<br />

Correct order is as following:<br />

M CODE INTERPREATION<br />

REG<br />

MF<br />

FIN<br />

a. When executing M77, 77 will be entered into REG 1.<br />

b. Assumed M Code and motion command are in the same BLOCK. If want M Code to<br />

execute its command after motion command is completed, then m code must coordinate<br />

with Distribution End(DEN)command under LADDER control.<br />

c. M00, M01, M02, M30, M98, M99 has no such simultaneous motion.<br />