<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1070 1ST SPD RIGTAP ACC. FILTER<br />

Range: 0 ~ 20<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description the bigger the value, the less vibration will occur and the<br />

:<br />

smaller of the following error. But, it is NOT absolute, which means there is<br />

an optimal value under certain filter intensity. When enter 0, it means there<br />

is no filting effect. When enter the maximum value (i.e., 20), it means there<br />

is a completely filting effect, which means the signal is filited completely.<br />

Please adjust this parameter setting value during the rigid tapping machine<br />

adjustment.<br />

1071 1ST SPD RIGTAP OUTPUT INVERSE<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description When the spindle +ive rotating direction under rigid tapping is<br />

:<br />

not the same as that under not rigid tapping mode, please set this parameter to<br />

1. Please adjust this parameter setting value during rigid tapping machine<br />

adjustment.<br />