<strong>LNC</strong>-<strong>M600</strong><br />

SYSTEM ALARM and WARNING<br />

INT 3126:BLOCK NOT FOUND<br />

(1)The designated BLOCK is not found.<br />

(2)Check whether or not the designated BLOCK is exist in part program.<br />

(3)Press RESET to clear wrong message error.<br />

INT 3127:ILLEGAL LABEL<br />

INT 3128:FEEDRATE OUT OF RANGE, CHECK G94/G95<br />

(1)Check G94 and G95 are used correctly.<br />

(2)Check whether or not the FEEDRAT F value is too big.<br />

(3)Press RESET to clear the error and adjust G94, G95 and F value.<br />

INT 3130:COORDINATE ERROR<br />

INT 3131:UNKNOWN PLANE<br />

INT 3132:ILLEGAL RADIUS<br />

(1)Using G02, G03 arch cutting command, the final coordinate is NOT on the arch<br />

(2)Check the position of center point, direction and final point’s coordinate value<br />

(3)Press RESET to clear error.<br />

INT 3140:SEND TABLE ERROR<br />

INT 3141:NO FREE VARIABLES<br />

INT 3150:INSUFFICIENT DATA<br />

(1)Not enough executing G code data.(Lack of G10’s P,R,Z)<br />

(2)Supply the needed data.<br />

(3)Press RESET to clear wrong warning message.<br />

INT 3151:IP MAINTAIN ERROR<br />

INT 3152:CC R RETURN<br />

(1)Executing G27,G28,G29,G30 in the CANNED CYCLE.<br />

(2)Cancel the above G codes in CANNED CYCLE before executing.<br />

(3)Press RESET to clear wrong warning message.<br />

<strong>LNC</strong> Technology Co., Ltd. 265