<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1035 2ND X- SOFT LIMIT<br />

1037 2ND Y- SOFT LIMIT<br />

1039 2ND Z- SOFT LIMIT<br />

1041 2ND 4- SOFT LIMIT<br />

Range: -99999999 ~ 99999999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default -99999999<br />

value:<br />

Unit: um<br />

Description<br />

:<br />

this parameter is to set the limitation value of the -ive X axis software travel limit.<br />

It works only after X axis is completed zero return procedure, or using the<br />

rebooting default value 99999.999 um. If this parameter setting value is larger<br />

than parameter # 1034 (+ive X axis<br />

software travel limit), it will enable the alarm system (MOT 4023, 2 nd software<br />

traveling limit setting error). The -ive X axis 1 st and 2 nd software traveling limit is<br />

able to execute exchanging through C BIT 141. Please refer to the description<br />

of C BIT. Under the condition that the -ive X axis 1 st software traveling limit is<br />

enabled, when X axis will excess the restricted range, it will enable the alarm<br />

system (MOT 9002 X axis over the –ive software travel limit) or (MOT 4058 over<br />

the software travel limit). Please refer to the description of this warning<br />

message.<br />

1091 PROTAG<br />

Range: -360000 ~ 360000<br />

Active: Active After RESET<br />

Level: User<br />

Default 0<br />

value:<br />

Unit: um<br />

Description this parameter is to set the default angle for G68 coordinate rotating command.<br />

:<br />

1092 PSCRT<br />

Range: 1 ~ 99999999<br />

Active: Active After RESET<br />

Level: User<br />

Default 1<br />

value:<br />

Unit: Nul<br />

Description when the setting value of parameter# 0143 is 1 (X, Y and Z axes zoom in/out<br />

:<br />

scale is determined by I, J and K of G51 zoom in/out scale command), this<br />

parameter is to set the default zoom in/out scale of X-axis.<br />