<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

14 G01 ACC/DEC TIME<br />

Range: 3 ~ 1500<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 100<br />

value:<br />

Unit: ms<br />

Description This parameter is to set the acceleration/deceleration time of G00 on ALL<br />

:<br />

SERVO AXIS. The smaller this parameter is, the faster the servo axis reach the<br />

specified speed; vibration, however, would be more indispensable. In 486IPC<br />

version (the IPO is 10ms), the max. value is 2000; in 586IPC version (the IPO is<br />

3ms), the max. value is 1500.<br />

If the set value exceeds the above limit, the 【MOT 4030 set error in X-axis G00<br />

acceleration/deceleration (parameter #0014) 】 warning message will be<br />

stimulated.<br />

24 CHANNEL NO FOR X AXIS<br />

25 CHANNEL NO FOR Y AXIS<br />

26 CHANNEL NO FOR Z AXIS<br />

27 CHANNEL NO FOR 4 AXIS<br />

Range: 0 ~ 6<br />

Active: Active After Reboot<br />

Level: Machinery Builder<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

if X(Y、Z、4 th ) axis is wired to the Nth-axis port e Transit board, this parameter is<br />

set to N. If no motor is connected, then this parameter is set to 0.<br />