<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

<strong>Manual</strong><br />

Progra<br />

Actual<br />

Program<br />

Interrupt Point<br />

Disable MANUAL RETURN<br />

Other than using this parameter to set MANUAL RETURN function, C BIT 0004<br />

can also be used:<br />

If C BIT 004 is ON, it means enable MANUAL RETURN function.<br />

If C BIT 004 is OFF, it means disable MANUAL RETURN function.<br />

Moreover, if the Parameter #0180 is 1, MANUAL RETURN function will be<br />

enabled no matter C BIT 004 is enable or not. On the other hand, if Parameter<br />

#0180 is 0, C BIT 004 does matter whether or not to enable this function.<br />

187 FEED RATE CLAMPING<br />

Range: 0 ~ 1<br />

Active: Active After RESET<br />

Level: User<br />

Default 0<br />

value:<br />

Unit: Nul<br />

Description<br />

:<br />

0:No<br />

1:Yes<br />

There will be a error amount ΔR between arch commanding and actual path.<br />

△R<br />

R<br />