<strong>LNC</strong>-<strong>M600</strong><br />

Parameter<br />

1075 1ST SPD SERVOLAG LIMIT<br />

Range: 0 ~ 100000<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 4096<br />

value:<br />

Unit: Pulse<br />

Description when rigid tapping machine adjustment is complete, please set the value or the<br />

:<br />

allowable following error that is 5-10 times larger of the display value from data<br />

system #26 at DGNOS page. If this setting value is too small, it is possible to<br />

cause the system alarm (MOT 055 rigid tapping spindle servo error is over the<br />

allowable limit) to occur during rigid tapping.<br />

1096 MAX SPEED OF 1ST SPINDLE<br />

Range: 0 ~ 99999<br />

Active: Active After RESET<br />

Level: Machinery Builder<br />

Default 6000<br />

value:<br />

Unit: RPM<br />

Description this parameter is used to set the max rotational speed ofspindle. When spindle<br />

:<br />

command rotational speed, which is set by user, islarger than this Parameter<br />

setting value, the system will restrict the spindlerotational speed according to<br />

this parameter setting value.<br />