<strong>LNC</strong>-<strong>M600</strong><br />

SYSTEM ALARM and WARNING<br />

6.4 MOT MOTION RELATED ALARM<br />

MOT 4001:X-AXIS ERROR COUNTER OVERFLOW<br />

(1)Motion board X- Axis ERROR COUNTER overflow(16-BIT).<br />

(2)Check or not the commanding speed is too fast.<br />

(3)Check whether or not servo motor is working normally.<br />

(4)Check whether or not the machine is running normally.<br />

(5)Check whether or not the board is normal.<br />

MOT 4002:Y-AXIS ERROR COUNTER OVERFLOW<br />

(1)Motion board Y-AXIS ERROR COUNTER overflow(16-BIT)<br />

(2)Check or not the commanding speed is too fast.<br />

(3)Check whether or not servo motor is working normally.<br />

(4)Check whether or not the machine is running normally.<br />

(5)Check whether or not the board is normal.<br />

MOT 4003:Z-AXIS ERROR COUNTER OVERFLOW<br />

(1)Motion board Z-AXIS ERROR COUNTER overflow(16-BIT)<br />

(2)Check or not the commanding speed is too fast.<br />

(3)Check whether or not servo motor is working normally.<br />

(4)Check whether or not the machine is running normally.<br />

(5)Check whether or not the board is normal.<br />

MOT 4004:4TH-AXIS ERROR COUNTER OVERFLOW<br />

(1)Motion board 4th-AXIS ERROR COUNTER overflow(16-BIT)<br />

(2)Check or not the commanding speed is too fast.<br />

(3)Check whether or not servo motor is working normally.<br />

(4)Check whether or not the machine is running normally.<br />

(5)Check whether or not the board is normal.<br />

MOT 4005:SET FIRST SOFT LIMIT ERROR<br />

(1)Error setting of 1st soft limit parameter (i.e., +ive soft limit is smaller than –ive soft<br />

limit) Please check parameter numbers 1006~1013.<br />

(2)Clicking RESET to set new parameter.<br />

(3)After changing the parameter, please reboot.<br />

268 <strong>LNC</strong> Technology Co., Ltd.