SYSTEM ALARM and WARNING<br />

INT 3006:DIVIDED BY 0<br />

(1)MACRO is divided by 0.<br />

(2)Modify numerator of the division. Must NOT be 0.<br />

(3)Press RESET to clear the wrong warning message.<br />

INT 3007:VARIABLE OVER RANGE<br />

(1)One/some of local variables, common variables and global variables are out of<br />

range.<br />

(2)Modify variable numbers that are out of their number range.<br />

(3)Press RESET to clear the wrong warning message.<br />

INT 3008:MACRO DOMAIN ERROR<br />

(1)MACRO function domain error. If square (SQRT) argument is negative or ATAN<br />

arguments are two zeros.<br />

(2)Modify domain.<br />

(3)Press RESET to clear the wrong warning message.<br />

INT 3010:NOT ALLOWABLE DECIMAL POINT<br />

(1)NC address has not allowable decimal point.<br />

(2)Modify decimal point in NC address.<br />

INT 3011:WORD DATA OVER RANGE<br />

(1)NC address word data is out of range.<br />

(2)Modify word data in NC address.<br />

(3)Press RESET to clear wrong warning message.<br />

INT 3012:MACRO ILLEGAL MACRO PARAMATER INPUT(G、L、N、O、P)<br />

(1)Illegal arguments(G,L,N,O,P)in MACRO program.<br />

(2)Correcting these illegal arguments.<br />

(3)Press RESET to clear wrong warning message.<br />

INT 3050:TOOL DIAMETER IS 0<br />

INT 3051:ILLEGAL RPM GIVEN<br />

INT 3052:ILLEGAL FEEDRATE GIVEN<br />