12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT019110 – General Commissioning RequirementsIssue Date:October 17, 2012Page #:19 <strong>of</strong> 301. The Contractor shall maintain an ongoing, current project schedule to provide a thirty (30) day lookahead <strong>of</strong> key project milestones to all projectteam members, including the CxA.2. At least (10) working days prior to the scheduled startup, the contractorshall coordinate startup and checkout with the CM, engineer, and CxA.The execution and approval <strong>of</strong> the construction checklists, startup, andcheckout shall be directed and performed by the contractor, subcontractoror vendor. Signatures are required <strong>of</strong> the applicable subcontractors forverification <strong>of</strong> completion <strong>of</strong> their work.3. The subcontractors and vendors shall execute startup and provide the CxAand engineer, through the Owner/CM, with a signed and dated copy <strong>of</strong> thecompleted startup and construction checklists.4. Only individuals <strong>of</strong> the contractor (technicians, engineers, tradesmen,vendors, etc.) who have direct knowledge and witnessed that a line itemtask on the construction checklist was actually performed shall check <strong>of</strong>fthat item. It is not acceptable for witnessing supervisors to fill out theseforms.5. Construction checklists must be completed, signed and dated prior to theCxA commencing functional testing.CHECKLIST SIGNOFF:Sign<strong>of</strong>f <strong>of</strong> this form constitutes approval from the Contractor and Construction Manager that the equipment has been properly installed, started up, contractor tested and isfully ready for functional demonstration as specified in the project specifications andsubmittals. The Contractor and Construction Manager accept responsibility for retesting if the systems are found to be incomplete. The sign<strong>of</strong>f MUST be completed priorto the functional testing phase <strong>of</strong> commissioning.ContractorCompany Contact Name Contact Signature DateConstruction ManagerI. Deficiencies, NonConformance and Approval in Checklists and Startup (MasterIssues Log).1. The contractor shall ensure that the subcontractors clearly list any outstanding items <strong>of</strong> the initial startup and construction checklist proceduresGENERAL COMMISSIONING REQUIREMENTS 01910 19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!