12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating15241 – Vibration Control<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Page #:6 <strong>of</strong> 8<strong>of</strong> the longest dimension <strong>of</strong> base, but not less than 6" deep. Size so that theweight <strong>of</strong> frame plus concrete fill will be greater than operating weight <strong>of</strong>equipment supported. Provide steel reinforcing both ways with both ends <strong>of</strong>reinforcing buttwelded to base framing. Provide welded support brackets forconnection to spring isolator units.L. Ro<strong>of</strong> Curb Isolators (Type D): Fabricated frame units sized to match ro<strong>of</strong> curbs,formed with isolation springs between extruded aluminum upper and lowersections, which are shaped and positioned to prevent metal to metal contact.Provide continuous airtight and waterpro<strong>of</strong> seal between upper and lowerextrusions. Include provisions for anchorage <strong>of</strong> frame unit to ro<strong>of</strong> curb, and foranchorage <strong>of</strong> equipment to unit.M. Flexible Pipe Connectors:1. For nonferrous piping, provide bronze hose covered with bronze wirebraid with copper tube ends or bronze flanged ends, brazewelded to hose.2. For ferrous piping, provide stainless steel hose covered with stainless steelwire braid with NPT steel nipples or 150 psi ANSI flanges, welded tohose.3. Flexible Pipe Connectors: Provide neoprene or EDPM constructionconsisting <strong>of</strong> multiple plies <strong>of</strong> nylon tire cord fabric and elastomer moldedand cured in hydraulic rubber presses. Provide straight or elbowconnector as indicated, rated at 125 psi at 220°F.PART 3– EXECUTION3.1 INSPECTIONA. Examine areas and conditions under which vibration control units are to beinstalled. Do not proceed with work until unsatisfactory conditions have beencorrected in manner acceptable to Installer.3.2 PERFORMANCE OF ISOLATORSA. General: Comply with minimum static deflections recommended by ASHRAE,for selection and application <strong>of</strong> vibration isolation materials and units asindicated.VIBRATION CONTROL152416

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!