12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Title:15900 – Direct Digital Control SystemPage #:24 <strong>of</strong> 40The output ID 420 MA or 010 VDC current compatible withcontroller.F. Status and Safety Switches1. Current Sensing Switchesa. Current sensing switch shall be selfpowered with solid state circuitryand a dry contact output. It shall consist <strong>of</strong> a current transformer, a solidstate current sensing circuit, adjustable trip point, solid state switch,SPDT relay and an LED indicating the on or <strong>of</strong>f status. A conductor <strong>of</strong>the load shall be passed through the window <strong>of</strong> the device. It shallaccept over current up to twice its trip point range.2. Low Temperature Limit Switchesa. The low temperature limit switch shall be <strong>of</strong> the manual reset type withDouble Pole/Single Throw. Snap acting contacts shall be rated for 16amps at 120VAC.b. The sensing element shall be a minimum <strong>of</strong> 15 feet in length and shallreact to the coldest 18 inch section. Mount element horizontally acrossduct in accordance with manufacturers recommended installationprocedures.c. For large duct areas where the sensing element does not provide fullcoverage <strong>of</strong> the air stream, provide additional switches as required toprovide full protection <strong>of</strong> the air stream.G. Temperature Sensors1. General Requirementsa. Input/output sensors and devices shall be closely matched to therequirements <strong>of</strong> the remote panel for accurate, responsive, noisefreesignal input/output. Control input response shall be high sensitivity andmatched to the loop gain requirements for precise and responsivecontrol.b. Temperature sensors shall be Resistance Temperature Detector (RTD)type <strong>of</strong> 100, 1000, or 3,000 ohm platinum, 500 ohm Balco, or 20,000ohm.c. The following shall apply to temperature sensors:1.) Stem or tip sensitive types.2.) Sensing elements shall be hermetically sealed.3.) Stem and tip construction shall be 304 stainless steel, copper,glass, or epoxy.4.) External trim material shall be corrosion resistant designed forthe intended application.2. Room Temperature Sensorsa. Room sensors shall be constructed for surface mounting.b. Room sensors shall have the following options:DIRECT DIGITAL CONTROL SYSTEMS1597224

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!